RS300 CONTINUOUS RADON MONITOR
- Accurate measurements in a wide range of temperatures and humidity
- Internal memory
- Print or download to a laptop or desktop computer (printer and software
sold separately)
- Lightweight, durable and tamper-resistant
- Software CD for downloading to your laptop or desktop PC
- Continuous measurement of radon gas - Provides hourly and average
readings
- Internal memory
- AC power / battery operation - Unaffected by power surges or
fluctuations
- Accurate measurements in a wide range of temperatures and relative
humidity
- Nominal sensitivity: 0.2 cpm/pCi/L - Favorably compares to many
higher end modelsIonization chamber detector
- Field worthy, sturdy construction
- No moving parts - No pumps or filters to maintain or replace
- Annual calibration
- Minimal setup
- Easy tripod attachment
- Serial port for onsite printing (to optional printer) or computer
download
- Keyed operation
- Keypad lockout
- Instrument motion sensor
|
Measurement |
Radon Gas |
|
Radiation
Detected |
Rn-222 Alpha |
|
Principle
of Operation |
Pulsed Ionization Chamber |
|
Units |
pCi/L |
|
Sensitivity |
0.27 cpm/pCi/L |
|
Dynamic
Range |
0.5 to 150 pCi/L |
|
Linearity |
+/- 10% Best straight line |
|
Lower Limit
of Detection |
0.5 pCi/L |
|
Data
Storage (volatile) |
n/a |
|
Data
Storage (nonvolatile) |
Up to 240 readings, wrap on overrun |
|
Sampling
Mode |
Passive diffusion |
|
Measurement
Interval |
1 hour |
|
Maximum
Number of Intervals |
240 |
|
Continuous
Measurement Range |
1 hour to 10 days |
|
12-Hour
Test Delay |
No |
|
24-Hour
Test Delay |
No |
|
Shows
Minimum Radon |
Yes |
|
Shows
Maximum Radon |
Yes |
|
Shows Alpha
Counts |
Yes |
|
Calculates
Average Measurement |
Yes |
|
Data
Transfer Software (Windows) |
RadStar Data Capture Utility Version 3.1 |
|
|
|
|
Tilt Switch |
Yes |
|
A/C Power
Fail Detection |
Yes |
|
Key Switch
Lock-out |
Yes |
|
Display
Blackout |
n/a |
|
Battery
Saver Mode |
No |
|
Hourly
Humidity Measurement |
No |
|
Hourly
Temperature Measurement |
No |
|
|
|
|
Physical
Dimensions |
7"H x 8"W x 4.5"D |
|
Tripod
Mounts |
Yes |
|
Weight |
2.5 lbs |
|
Color |
Green/Black |
|
Operating
temperature |
50 - 90 deg F |
|
Operating
humidity |
0% - 80% rH non-condensing |
|
Temperature
Sensor Range |
n/a |
|
Humidity
Sensor Range |
n/a |
|
Display |
None |
|
Operating
Indicator(s) |
Green A/C Power, Red Testing LEDs |
|
Output |
RS-232 serial port |
|
Battery
Operation |
5 - 8 days; internal NiCad |
|
Battery
Recharge Time |
12 Hours |
|
Power
Supply |
AC Wall Transformer - 12 VDC 800ma |
Downloads
|