Call for quantity discounts. We can beat any
Advertised Price. 877-412-3600
Meets
EPA Performance Criteria
of the CR protocol. Our
electronic radon gas detector/monitor is
a proven performer being in service since 1996. Used by inspectors, consultants
and homeowners to monitor the radon gas levels in schools, offices and
residences. It is a solid state continuous radon monitor which utilizes patented
technology. At the heart of the device is a measurement circuit and pulse
processing software which records alpha events on a photovoltaic sensor. Radon
daughters create a spark when they come in contact with the potential across the
collection dome and the photovoltaic sensor counts these pulses. The software
equates pulse volume into pCi/L (Pico Curies per Liter) and then displays the
information on the LED display.
Follow this link for more technical info (will open in new window)
Features:
- No wiring or batteries
needed; uses typical 110v household current.
- Entela Certified
-
Results will display in approx
48 hrs on a numeric digital LED display
-
Shows the level of radon gas in
pCi/L on a short-term or long-term basis
- 2 modes of measurement - long & short term
-
Alarm sounds:
-
Long-term measurement reaches
4 pCi/L or greater (can be silenced)
- Short-term
measurement stays above 4
pCi/L
for 30
consecutive days
-
Samples air continuously;
display updated every hour.
-
Self-test every 24 hours with an
error code displayed if failure.
- 10' power cord supplied
-
Menu button controls 4
functions. Re-set unit and use in different locations.
- UL61010B-1:2003 Issued: 1/24/03 Ed: 1
Standard for Safety Electrical Measuring & Testing Equipment; Part 1: General
requirements
- CSA C22.2 NO 1010.1-92 - Safety Requirements
for Electrical Equipment for Measurement, Control and Laboratory Use, Part 1:
General requirements
-
10 year sensor and a 1 Year
warranty!
Specifications:
- Power
source input: 120 VAC / 60Hz at 6.5 Watts
- Power
source output: 18 VDC / 200mA
- Sensor:
Ionization Chamber
- Sensor
voltage: 250VDC
- Full
scale reading: 0.1 to 999.9 pCi/L
-
Operating temperature: 32° to 104° F (0° to 40° C)
- Storage
temperature: -4° to 185° F (-20° to 85° C)
- Audible
Alarm: 85dB at 10cm
- Beeps every hour if:
- long-term readings
are 4 pCi/L or greater or
- short-term
measurement stays above 4
pCi/L
for 30
consecutive days
-
Averaging frequency: Levels will be updated on the display every hour
-
Short-Term: Average over the past 7 days
- Long-
Term: Average from the time of last reset (5 year max) resets after 5 years
-
Accuracy: ±12%
pCi/L
(click here to see accuracy report in PDF format)
-
Dimensions: 4.7" x 3.1" x 2.1"
Supplied with:
|