The KM940 handheld analyzer is easy to use for domestic and industrial
boiler flue gas measurement and analysis. It operates on all boiler types and
can display 8 parameters simultaneously showing measurements and calculations of
boiler efficiency and pollution. It measures O2, flue and net T temperature and
calculates CO2, boiler efficiency, excess air and losses. CO is
measured with a hydrogen compensated sensor for increased accuracy. It also
measures CO and calculates CO/CO2 ratio (The Poison Index) to
give complete readings for effective boiler analysis and safety.
Features:
- Measures CO, O2, Inlet & Flue Temperature,
Differential Pressure (draft)
- Calculates Efficiency, Carbon Dioxide (CO2), Losses, Excess
Air, CO/CO2, Poison Index, Net Temperature Differential
- High suction double-headed diaphragm pump (can be used in flues with
suction over 100 mbar without compromising accuracy)
- Installed memory can store up to 150 readings and can transfer data to a
printer or PC (via Infra-red printer link)
- The printout displays the time and date of each measurement as well as personalized information such as company name and telephone number
- Long life rechargeable battery & Large 4 line display
- Optionally, it can also measure either NO2 or SO2
and can be fitted with CO and NO sensors with different measuring ranges
- add up to 3 additional sensors
Specifications:
|
|
Resolution |
Accuracy |
Range |
|
Temp Measurement |
|
Flue Temperature with Probe |
0.1º |
±2ºC ±0.3% |
32-1112ºF (0-600ºC) |
|
Inlet Temperature |
0.1º |
±1ºC ±0.3%
|
32-122ºF (0-50ºC) |
|
Pressure |
0.1 mbar |
±2% of full scale |
150mbar to -150mbar |
|
Gas Measurement * |
|
Oxygen O2 |
0.1% |
±0.2% |
0 to 21% |
|
Carbon Monoxide CO
(H2
compensated) |
1ppm |
±20ppm <400ppm+
±5% <5,000ppm
±10% <5,000ppm |
0 to 10,000ppm |
|
Calculations |
|
Carbon Dioxide CO2 * |
0.1% |
±0.3% |
0 to 99.9% |
|
Losses + |
0.1% |
±1.0% |
0 to 99.9% |
|
Efficiency + |
0.1% |
±1.0% |
0 to 99.9% |
|
Excess Air + |
0.1% |
±0.2% |
0 to 2885.0% |
|
Temp (Nett) + |
1.0º |
±2ºC (±0.3%) |
32-1112ºF (0-600ºC) |
|
CO/CO2 Ratio + |
0.0001 |
±0.0001 |
0 to 0.9999 |
|
Poison Index + |
0.01% |
±0.01 |
0 to 99.99 |
|
+ Using dry gases at STP
* Calculated |
- Pre-programmed Fuels: Natural Gas, Town Gas, Gascor, Light
Oil, Heavy Oil, Propane, Butane, Anthracite, Coke, Coal, Kinsale Gas
- Dimensions:
- Handset: 8.7" x 2.2" x 4.7" (220 x 55 x 120mm)
- Probe Length: 420mm, 8mm Diameter with 285mm stainless steel shaft, type K thermocouple and
1.5m neoprene hose
- Weight: 2.2 pounds
- Altitude to 2000m
- Ambient operating temperature range: 32º to 113ºF (0º to 45ºC)
- Ambient operating humidity range:10 to 90% RH non condensing
- Power supply (battery charger): Input: 110vAC / 220vAC; nominal Output: 12vAC off load
- Battery Life: >6 hours from full charge
- Probe & hose lined with Teflon to reduce absorption of sample gases
Supplied with:
- Teflon lined Flue gas probe, Battery & Battery charger
- Protective rubber boot, User's manual & Large Cordura carrying case
- One year limited manufacturer's warranty (2 year on O2
sensor)
Options: You can add up to 3 additional sensors
| GAS |
RANGE |
PART#
|
| CO (H2
Compensated) |
0~10,000ppm |
12933 |
| CO (Hi-Range) |
0~10% |
13911 |
| NO1 |
0~5,000ppm |
13251* |
| NO1 low range |
0~100ppm |
18079* |
| NO2 |
0~1,000ppm |
10533 |
| SO2 |
0~5,000ppm
|
13910 |
| SO2 low range |
0~100ppm |
18131 |
| |
*NOX will be
calculated only if NO1 sensor is installed. |
- Smoke Pump Test Kit:
SPT1
- Inlet Temperature Probe (6" Liquid K-Type):
ATT100
- Infrared Printer:
KMIRP2
Download Data Sheet (PDF format)
Download Users Manual (PDF format) |
|
 |
|
|
|
|
|
|
|
|
 |
Customers who bought this product also purchased: |
 |
|