TestProducts.com | National Safety Products | 877-412-3600
Test Kits, Tools, Meters & Safety Equipment!
[ 0 Items $0.00 0 lbs ]
My Account Cart Contents Checkout
Search Catalog:
Categories
BoreScope VideoScope

Carbon Monoxide

Combustion Analyzers

Fire & Smoke Safety

Flood & Water Alarms

Gas & Leak Detectors

GE Protimeters

Heat Index Monitors

Inspection Kits Mirrors

Lead, Mold & Drug Test

Light & UV Meters

Microwave - EMF Meters

Moisture Detectors

Power & Adapters

Radon Gas Test Kits

Radon Mitigation

Security & Safety

Smoke Emitters

Soil & Grain Moisture

Sound Level Meters

Specialty Meters

Temperature Humidity

Timers & Clocks

Tools & Hardware

Water Testing & Meters

Weather Instruments

View All Products
Quick Find
 
Search Catalog:
Advanced Search
Customer Service
About Us
Shipping Policy
Return Policy
Privacy Notice
Conditions of Use
Contact Us

UVA & UVC Data Logging Ultra Violet Light Meter (UV254SD) SD Card

Model #: UV254SD
$799.00

http://testproducts.com/data-logging-ultra-violet-light-meter-uv254sd-card-p-1592.html

Print Friendly View
Add Qty to Cart:  

UVA & UVC Data Logging Ultra Violet Light Meter (UV254SD) SD Card
Click to enlarge

Reviews
Previous Product Product 10 of 10 Next Product
Category Light & UV Meters

UVA & UVC Ultra Violet Light Meter includes a Real time SD memory card Datalogger, with Built-in Time/Date Stamp and real time data recorder (sampling time can be set at intrervals of 1 second to 3600 seconds).

  • Microprocessor circuit provides high reliability and durability. UVA, Long wave 365 nm ultra-violet irradiance measurement. UVC, Short wave 254 nm ultra-violet irradiance measurement.
  • 1 touch self calibration zero button
  • Datalogging is available in either automatic or manual mode.
  • Computer is not needed to setup extra software, after recording with the datalogger, just insert the SD card into your computer car reader, then upload all of the measured values with the time & date information (year/month/date/hour/minute/second) into your favorite spreadsheat software (CVS).
  • UltraViolet L-Sensor with cosine correction filter and has a heavy duty sensor structure with metallic housing case.
  • Remote probe allows measurement at optimum positions.
  • Tripod Mount & Self-storing easel back
  • Data hold, memory with recall, records Maximum & Minimum reading
  • Auto power off (can be disabled)
  • RS-232 PC computer interface.
  • SD card capacity : 1 GB to 16 GB.
  • Display size: 2" x 1.5" (52 x 38mm) LCD with green backlight
  • Spectrum range: 240 to 390nm.

Measurement ranges (auto switching) & resolution

Measurement Range Resolution Accuracy
Range 1 0.000 to 1.999 mW/cm^2 0.001

± (4 % FS + 2 digits)
FS : full scale

Range 2 2.00 to 19.99 mW/cm^2 0.01
  • Datalogger Sampling Time Setting range:
    • Automatic: 1 to 3600 seconds
    • Manual: Push the data logger button once to save one data point
  • Advanced Setting Options:
    • Set clock time (Year/Month/Date, Hour/Minute/ Second)
    • Decimal point of SD card setting
    • Auto power OFF management
    • Set beep Sound ON/OFF
    • Set thermometer type to Type K or Type J
    • Set temperature unit to ºC or ºF
    • Set sampling time
    • SD memory card Format
  • Temperature Measurement with ATC (can only be used when Light Probes are removed)
  • Type K or Type J thermocouple connection
Sensor Type Resolution Range Accuracy
Type K 0.1ºC -50.0 to 1300.0ºC ± ( 0.4 % + 0.5ºC )
-50.1 to -100.0ºC ± ( 0.4 % + 1ºC )
0.1ºF -58.0 to 2372.0 ºF ± ( 0.4 % + 1ºF )
-58.1 to -148.0 ºF ± ( 0.4 % + 1.8ºF )
Type J 0.1ºC -50.0 to 1200.0ºC ± ( 0.4 % + 0.5ºC )
-50.1 to -100.0ºC ± ( 0.4 % + 1ºC )
0.1ºF -58.0 to 2192.0 ºF ± ( 0.4 % + 1ºF )
-58.1 to -148.0 ºF ± ( 0.4 % + 1.8ºF )
  • Sampling Time: Approx. 1 second.
  • Data Output: RS-232 and SD card
  • Operating Temperature: 32º to 2372.0 ºF (0º to 50ºC)
  • Operating Humidity: Less than 85% RH
  • Power Supply: (6) AA 1.5v Alkaline or 1.2v NiMh or equivalent. (optional 9vDC power power adapter)
  • Power Current:
    • approx. DC 6.5 mA: Normal operation (no DataLogging, with LCD Backlight OFF)
    • approx. DC 30 mA: DataLogging mode (with LCD Backlight OFF)
    • with LCD backlight on, the power consumption will increase by approx. 16 mA
  • Weight: 1.08 lbs (489g) meter only
  • Dimensions:
    • Meter: 7" x 2.7" x 1.9" (177x68x45mm)
    • UVA Sensor: 0.6" diameter
      • Probe: 1.77" diameter x 1.3" (with 5" handle and 39" wire)
    • UVC Sensor: 0.7" diameter
      • Probe: 1.5" diameter x 1.1" (with 39" wire)

Applications: Low E, Dentistry, Monitoring blue light radiation hazards in welding, UV sterilization, Graphic Arts, Photochemical Matching, UV EPROM erasure, Photoresist exposure, curing of inks, adhesives and coatings.

Previous Product Product 10 of 10 Next Product
Category Light & UV Meters
Welcome
Login:
eMail Address:
Password:
Forgotten Password?
Click Here
First Time Visitor?
Click here
Information
Carbon Monoxide
Radon Gas Facts
Radon Results Lookup
Smoke Detector Testing
Specials more
Mini Vane Anemometer 1.1-93 MPH (DAF4000) Compass, Altitude, Pressure & Temp
Mini Vane Anemometer 1.1-93 MPH (DAF4000) Compass, Altitude, Pressure & Temp
$190.99 $139.00
Manufacturer Info
General Tools
Other products
Notifications more
Notify me of updates to UVA & UVC Data Logging Ultra Violet Light Meter (UV254SD) SD Card
What's New? more
Protimeter SurveyMaster LE (BLD5364) Non-invasive & Pin Moisture Meter
Protimeter SurveyMaster LE (BLD5364) Non-invasive & Pin Moisture Meter
$549.99 $409.00
Affiliate Program
Affiliate Information
Affiliate Program FAQ
Affiliate Log In
  Your IP Address is: 38.107.179.234
Copyright ©1996-2012 Testproducts.com

Thanks for visiting TestProducts.com. The Source for Test Kits, Smoke, Tools, Meters & Safety Equipment